7/13/2007 v2.12 Build 45: Profiles exceeding 1200 elements (50+ feet) properly grow their arrays.
12/11/2003 v1.31 Build 18: Porosity support.
10/31/2002 v1.30 Build 17: Closed captioning update.
8/3/1999 v1.21 Build 15: The proper DetServ.dll file is now distributed to fix calibration load errors.
8/3/1998 v1.21 Build 14: Soil Class labels converted to numeric values.
7/29/1998 v1.21 Build 13: Variable LIF window offset fixed for multi-window probes. Tiling one or more spectral plots w/o any profile plots (or one or more profile plots w/o any spectral plots) no longer crashes. Minor bug in the binary registry storage of default display window sizes fixed.
7/1/1998 v1.21 Build 10: LIF readings complete even when the hydraulic switch is release before LIF data is read. CC alternating output added.
5/14/1998 v1.20 Build 9: LIF data collection rewritten for asynchronous operation to allow faster and continuous geotechnical feedback readings. Closed-caption output reliability improved.
2/5/1998 v1.10 Build 8: Camera closed-caption output capability added. Distributing Release binaries.
11/21/1997 v1.01 Build 7: LIF profiles are drawn with a discontinuity between adjacent points (usually around 3 ft.) and retrace at the end to continue drawing back up to the discontinuity. The data is correct, but drawn out of order. This may only occur if you preload documentation, and is due to the Microsoft database engine returning out of sequence recordsets on unfiltered queries. This build filters all recordset queries to prevent this error.
10/29/1997 v1.01 Build 6: Preloading documentation from a push file that contains LIF records causes the first attempt to collect LIF data to fail. Also, showing statistics for noise spectra with a peak at the edge of the spectral array throws a debug assertion.
10/17/1997 v1.01 Build 5: This build adds a user-requested change, not a bug fix. The Maximum field in the database is calculated for every detector spectrum, including System Check and Background Check spectra.
10/9/1997 v1.01 Build 4: Attempting to import OCPT created PSH files will import only the documentation and geological sensor data before displaying a "No error occurred" message box. Dismissing the message returns to normal operation but no spectral or profile data is imported.
Automatic updates over the internet now work when WinOCPT is installed into a subdirectory with a pathspec that includes one or more spaces.
9/9/1997 v1.01 Build 3: The DAD program for system checks is incorrect in Builds 1 and 2. Build 3 contains the proper DAD program but you must remember to re-edit the default detector setup parameters. Help contents are improved in this build, also.